Containers at the port terminal
Home / Glossary / Fumigation

Fumigation. A treatment not to underestimate.

Fumigation is treatment with a gas, such as phosphine, to eliminate insects and pests from goods, packaging and containers. A fumigated container carries a warning mark and must be ventilated before opening, because residual gases can be toxic. It is not the same as the heat treatment of wood required by the ISPM 15 standard.

Glossary · Sea freightUpdated 27 November 20264 min read

What it is and why it is done

Some countries require certain goods or their packaging to arrive free of insects and harmful organisms. To meet this, fumigation can be used: the container, or the goods, is saturated with a gas that kills the pests, and then left to air. It may be required by the destination country, by the contract or by the nature of the goods, for example agricultural products, unprocessed wood or pellets in sacks.

It should not be confused with the treatment of wood packaging under the international standard ISPM 15 (pallets, crates, dunnage), which is generally done with heat and certified by a mark on the wood; for details see the ISPM 15 guide and the entry ISPM 15. Fumigation concerns the inside of the container and the goods, although the two treatments can coexist.

Where and when it takes place

  • Before loading: the treatment is done in an authorised facility, or in the closed container with a licensed operator, and ends with ventilation.
  • During the voyage: sometimes the fumigant stays in the container during transport; this is the most delicate situation and requires clear signage.
  • On arrival: the destination country may order treatment of the container, at the importer's expense, if the goods or packaging do not comply with the rules.

Markings and safety rules

A fumigated container must carry a clearly visible warning label on the doors, with the essential information: the fumigant used, the date and time of treatment, the duration and the precautions. The IMO has issued recommendations on the fumigation of transport units and the CTU Code contains a dedicated annex. In the IMDG Code for dangerous goods by sea there is a specific entry, UN 3359, for fumigated transport units, with marking and documentation rules.

The shipper must declare the fumigation to the carrier: a fumigated container is treated as hazardous cargo, even if the goods themselves are not dangerous. If it is not declared, whoever opens it is exposed without knowing. On this subject see also dangerous goods by sea.

Risks for whoever opens the container

  • The gases used are toxic and do not always have an odour: the absence of odour alone is not enough.
  • Before entering the container must be aired with the doors open and the residual concentration checked with instruments.
  • Opening must be done by informed staff, in the open air, without leaning over the doors.
  • If the marking is missing or the data are uncertain, the container is treated as potentially dangerous and a licensed operator is called in.

Containers may contain fumigation residues even when nobody has declared them, for example if the treatment was done at origin; that is why stripping always requires a preliminary check.

A practical example

A company imports from a non-EU country a container of treated wood products. On arrival the container carries the fumigation sign. The freight forwarder warns the consignee, who has the container ventilated by a licensed firm, checks the values and only then starts unloading. At customs, the attached phytosanitary certificate confirms the treatments carried out.

Common mistakes

  • Not declaring the fumigation to the carrier and the consignee.
  • Opening the container without ventilating it.
  • Confusing fumigation with the ISPM 15 mark on wood.
  • Forgetting that some countries require a fumigation or phytosanitary certificate already at departure.

For FCL shipments and packaging checks, tell Dalè in advance about treatments and destination country requirements.

Sources

  1. IMO - CTU Code (annex on fumigation)
  2. IPPC - ISPM 15, wood packaging

A shipment to organise?

Tell us what you are shipping and where to: we reply with the route, the documents required and a quote.

Related Dalè services

Related glossary terms

FAQ

Quick answers.

What is container fumigation?

It is treatment with a gas, such as phosphine, to eliminate insects and pests from goods and packaging. The fumigated container carries a warning label and must be ventilated before opening.

Are fumigation and ISPM 15 the same thing?

No. ISPM 15 concerns wood packaging, generally treated with heat and marked; fumigation concerns the inside of the container or the goods. The two treatments may be required together.

How do I recognise a fumigated container?

By the warning label on the doors, showing the fumigant, date, time and precautions. If it is missing but there is doubt, the container must be treated as dangerous and checked by a licensed operator before opening.

Does fumigation have to be declared to the carrier?

Yes. The fumigated container falls among the units with specific rules also in the IMDG Code (UN 3359). Not declaring it exposes whoever opens the container to risks and can lead to penalties.