Container ship at sea
Home / Glossary / Class 5 – Oxidisers and organic peroxides

Class 5 – Oxidisers and organic peroxides. Oxygen that feeds the fire.

Class 5 brings together two divisions: oxidisers (5.1), which by giving off oxygen help other materials to burn, and organic peroxides (5.2), thermally unstable substances that can decompose violently. They are not necessarily flammable in themselves, but they make fires far more dangerous and must be kept away from combustible materials.

Glossary · Dangerous goodsUpdated 27 November 20265 min read

What it includes

Fire needs fuel, ignition and oxygen. Class 5 materials supply the third element: either because they contain oxygen that they release easily (the oxidisers), or because their unstable chemical structure makes them decompose, releasing heat and gas (the organic peroxides). A fire in the presence of an oxidiser burns harder, faster and can be difficult to put out. For this reason the basic rule, in every mode of transport, is to keep these products away from combustible materials and from other dangerous goods with which they react.

5.1 Oxidising substances

Oxidisers can be solids, liquids or gases (oxidising gases, such as oxygen, are however in class 2 with a 5.1 subsidiary hazard). Examples in common use:

  • ammonium nitrate and nitrates in general, used in fertilisers;
  • hydrogen peroxide, in concentrated solutions;
  • hypochlorites and chlorates, found in pool and disinfection products;
  • permanganates and persulphates, used in the chemical industries and in treatments.

The label shows a flame over a circle, on a yellow background. The classification criterion is based on UN tests that measure the burning rate of a mixture with a reference combustible material. The result decides the packing group: the higher the rate, the stricter the group.

5.2 Organic peroxides

Organic peroxides contain the oxygen-oxygen bond, which breaks easily. They are used as initiators in the production of plastics, resins and fibreglass, and as catalysts. They can decompose explosively through heat, impact, friction or contamination. They are classified into seven types, from A to G, according to their hazard: type A is not allowed for transport in the form in which it is tested, while types B-F have packing instructions with quantity limits per package, and type G is not subject to the rules of the class. Many peroxides have a control temperature and an emergency temperature: the product must be carried at a temperature below the first, and if control is lost, the emergency procedures are triggered. The label is half red and half yellow, with a flame.

Segregation and stowage

Segregation is the main issue. Oxidisers must be kept away from flammable liquids, from combustible materials such as wood, cardboard, paper and textiles, from strong acids and from many class 4 substances. The ADR does not allow mixed loading with substances with which oxidisers react; the IMDG Code gives separation levels between 5.1 and the other classes. In containers it is advisable to avoid wooden pallets and combustible packaging materials close to oxidisers. Ammonium nitrate too has strict rules because of the possibility of decomposition under fire or in large quantities.

Road, sea and air

By road, transport is subject to the ADR regime with the usual equipment, and quantities are limited by the transport categories. Some oxidising substances also have a corrosive hazard, such as concentrated hydrogen peroxide, and carry two labels. By sea, organic peroxides with a control temperature are often accepted only in refrigerated containers with monitoring of the temperature data: the shipping line checks case by case. By air the IATA DGR set strict limits per package and many peroxides are allowed only on cargo aircraft or prohibited. In every mode the safety data sheet must state the UN number and, for peroxides, the type and the control temperatures.

Data to have before booking

For an oxidiser the safety data sheet and the UN number are usually enough, but the packing group must be checked, because the same trade name can correspond to different concentrations and therefore to different entries: hydrogen peroxide at 35% is not carried like the one at 8%. For organic peroxides you also need the type (B to F), the concentration, the diluent, the control temperature and the emergency temperature. The transport document shows these values when required and the wording on temperature control. Without this data the carrier cannot assess acceptance or plan the vehicle.

A practical example

A company in Brescia that makes fibreglass articles has to ship drums of an organic peroxide used as a catalyst, type D, with a control temperature of 20 °C, to France. The transport must stay below that threshold: it needs a refrigerated vehicle, temperature monitoring and precise instructions for the driver. In a hot summer period the choice of day, departure and delivery is decisive. A flammable solvent, for example, cannot travel together with the drums. Dalè checks the data sheet, the classification and the compatibility of the whole load before arranging the departure.

Common mistakes

  • Loading oxidisers with flammable liquids or on highly combustible pallets.
  • Not respecting the control temperature of organic peroxides.
  • Overlooking a corrosive subsidiary hazard.
  • Treating the ammonium nitrate in fertilisers as non-dangerous goods without checking the entry.
  • Using packaging material that is incompatible with the oxidiser.

Sources

  1. UNECE - UN Recommendations and Manual of Tests
  2. IMO - IMDG Code

A shipment to organise?

Tell us what you are shipping and where to: we reply with the route, the documents required and a quote.

Related Dalè services

Related glossary terms

FAQ

Quick answers.

What is the difference between an oxidiser and an organic peroxide?

An oxidiser (5.1) gives off oxygen and helps other materials to burn. An organic peroxide (5.2) is unstable and can decompose violently even on its own. The two divisions have different labels and rules.

What is the control temperature?

It is the maximum temperature at which an organic peroxide must be kept during transport. If the emergency temperature is exceeded, the emergency procedures are triggered. The value depends on the substance.

Are fertilisers with ammonium nitrate dangerous goods?

It depends on the composition. Some fertilisers have their own entry in class 5.1 or in class 9, others are excluded because of their nitrate and combustible content. You must always check the entry from the safety data sheet.

Your next project

Your next shipment starts here.

Map of Dalè's headquarters in Via Bruno Buozzi 14, Brescia Via Bruno Buozzi, 14 · BresciaDirections ↗ © OpenStreetMap

Request a quote