What it includes
In the transport rules a gas is defined by its physical behaviour, not by its name: it is a substance that at 50 °C has a vapour pressure greater than 300 kPa, or is completely gaseous at 20 °C and standard pressure of 101.3 kPa. Class 2 includes pure gases, gas mixtures, gases with vapours of other substances, articles that contain gas and also aerosols (UN 1950), which have their own rules. Everyday examples are LPG, oxygen, nitrogen, argon, acetylene, fire extinguishers, spray cans and refrigerant gases.
How they are found in the receptacle
The physical state in the receptacle counts as much as the chemical nature. The rules distinguish:
- compressed gases, completely gaseous at -50 °C under pressure;
- liquefied gases, partially liquid at temperatures above -50 °C under pressure;
- refrigerated liquefied gases, partially liquid because of the low temperature (such as liquid nitrogen in cryogenic containers);
- dissolved gases, dissolved in a solvent under pressure, such as acetylene in a cylinder;
- aerosols and small receptacles with gas, the so-called cartridges.
The three divisions and the labels
The class is divided according to the main hazard. The classification code is often cited: the letter A indicates an asphyxiant, O an oxidising gas, F a flammable one, T a toxic one, and the combinations TF, TC, TO for cases with several hazards.
- 2.1 Flammable gases: label with a flame on a red background. Examples: butane, propane, hydrogen, acetylene.
- 2.2 Non-flammable, non-toxic gases: label with a gas cylinder on a green background. It includes inert gases such as nitrogen and argon, asphyxiants, and oxidising gases such as oxygen, which also carry the class 5.1 label.
- 2.3 Toxic gases: label with a skull on a white background. Examples: chlorine, anhydrous ammonia, carbon monoxide.
Some gases have subsidiary hazards: anhydrous ammonia is toxic and corrosive, chlorine toxic and oxidising. Subsidiary hazards are taken from the table and must be shown with the corresponding labels. Class 2 has no packing groups, because the hazard depends on the gas and the type of receptacle, not on a grading.
Pressure receptacles
The hazard of the gas also lies in the receptacle: a cylinder that falls or overheats can explode or turn into a projectile. For this reason cylinders, pressure drums, tubes and tanks for gases are built and tested according to standards, with the marking on the shoulder of the receptacle: test pressure, date of the last test, owner or manufacturer. Receptacles must undergo periodic checks at set intervals. A receptacle whose test has expired is not filled or transported, and one with a damaged valve or illegible marking is taken out of use.
The packing instructions, for example P200 of the ADR, give for each gas the maximum filling pressure and the conditions. Valves must be protected with caps or similar systems and the receptacles must be stowed so that they do not roll or knock against each other.
Road, sea and air
By road many gases in cylinders travel with the transport document and the equipment required. The quantities carried on a vehicle follow the transport category and the exemption thresholds (the 1,000-point rule). By sea the IMDG Code requires specific stowage, often on deck for flammable and toxic gases, and segregation from acids, oxidisers and other incompatible goods. By air the IATA DGR allow gases with tight limits, and many are permitted only on cargo aircraft: CAO. Some cylinders, such as refrigerants, are prohibited on board passenger flights in quantities above the limits.
A practical example
A metalworking company in Brescia ships to a customer in Switzerland cylinders of argon-CO2 for welding, class 2.2, and two cylinders of acetylene, class 2.1. Acetylene is a dissolved gas, with its own filling limits: the two divisions have different labels and are checked separately, also for mixed loading. The vehicle will need the suitable equipment and, if the exemption thresholds are exceeded, the driver will need the ADR certificate. Dalè checks tests, markings and documents in its own warehouse in Brescia before collection.
Common mistakes
- Shipping cylinders with an expired test.
- Forgetting the subsidiary hazard, for example the oxidising property of oxygen.
- Not protecting the valves.
- Treating an "empty" cylinder as not dangerous: uncleaned empty receptacles remain subject to the rules.
- Stowing flammable gas and oxidising gas cylinders together.
Sources
A shipment to organise?
Tell us what you are shipping and where to: we reply with the route, the documents required and a quote.
Related Dalè services
Related glossary terms