What it measures
A liquid does not burn as a liquid: what burns is the vapour that forms above its surface. The hotter the liquid, the more vapour it produces. The flash point is the temperature at which, for the first time, this vapour is enough to catch fire briefly if a flame or spark is brought near. It is not the temperature at which the liquid "ignites by itself", which is called the auto-ignition temperature and is something else.
How it is measured
It is measured in a laboratory with standardised instruments. The two main approaches are the closed cup method, in which the liquid is in a covered container and the vapour accumulates, and the open cup method, which usually gives slightly higher values. For the carriage of dangerous goods, reference is made to the closed cup methods among those indicated by the ADR. The result is expressed in degrees Celsius.
The figure is not invented and not estimated: it is supplied by the manufacturer, who states it in the safety data sheet, in section 9 on physical and chemical properties. For mixtures the value depends on all the components, and sometimes a small quantity of volatile solvent lowers the flash point of the whole a great deal.
What it decides in transport
Class 3 includes liquids with a flash point of up to 60 °C, plus some special cases such as liquids carried hot. Within the class, the packing group is assigned by combining the flash point and the initial boiling point:
- group I: initial boiling point not above 35 °C;
- group II: flash point below 23 °C and initial boiling point above 35 °C;
- group III: flash point from 23 °C up to 60 °C.
The packing group in turn determines the type of packaging, the quantity limits and other rules. A mistake on the flash point therefore spreads to the whole shipment.
In sea transport the IMDG Code also requires that the flash point appear in the declaration when it is 60 °C or lower, in degrees Celsius and with the indication of closed cup. For the IATA DGR and the ADR the figure is used for classification, but does not always have to be shown in the documents.
Difference from the GHS classification
The classification of flammable liquids in the CLP Regulation uses four categories: the fourth goes up to 93 °C, beyond the 60 °C limit of transport. A product with a flash point of 75 °C can therefore be "flammable" on the label but not be a class 3 dangerous good in transport. For diesel fuels there is a specific exception: they are assigned to class 3 even with a flash point of up to 100 °C. Reading only the product label, therefore, is not enough.
A practical example
A company in Brescia ships two similar products: a paint with a flash point of 18 °C and a thinner with a flash point of 45 °C. The paint is class 3, group II; the thinner is class 3, group III. The permitted packagings and the limits for limited quantities change. If the figure on the data sheet were wrong or out of date, classification and packagings would be wrong. For this reason Dalè compares the figure on the data sheet with the entry in the table before preparing the documents.
Common mistakes
- Confusing the flash point with the auto-ignition temperature.
- Using the open cup value instead of the closed cup one.
- Taking the value of a component instead of that of the mixture.
Sources
A shipment to organise?
Tell us what you are shipping and where to: we reply with the route, the documents required and a quote.
Related Dalè services